This standard describes a SAR preparation method, acceptable to DOE, which was developed to assist Hazard Category 2 and 3 facilities in preparing SARs that will satisfy requirements of DOE 5480.23. (Hazard Category 1 facilities are typically Category A reactors for which extensive precedents for SARs already exist.) The methodology in this standard focuses more on facility safety (back-end approach) with or without design information than on facility design (front-end approach).

Research Organization:
US Department of Energy (USDOE), Washington DC (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
OSTI ID:
10171907
Report Number(s):
DOE-STD-3009-94; ON: DE94016340; NC: NONE
Resource Relation:
Other Information: PBD: Jul 1994
Country of Publication:
United States
Language: