Maintenance study for W-340 Waste Retrieval System
This study was performed to identify attributes and maintainability requirements for the Tank Waste Retrieval System (TWRS). The system will be developed for Westinghouse Hanford Company in Richland, Washington, as an integrated system to perform waste removal in Tank C-106 and, thus, demonstrate technologies for tank remediation that will satisfy requirements of the Tri-Party Agreement. The study examines attributes of the TWRS, scope of maintenance operations required for the TWRS, maintenance requirements, and potential methods of performing maintenance functions. Recommendations are provided for consideration in the development of both the conceptual design and performance specification, which will be used in procuring the W-340 Waste Retrieval System.
- Research Organization:
- EG and G Idaho, Inc., Idaho Falls, ID (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC07-76ID01570
- OSTI ID:
- 10168319
- Report Number(s):
- EGG-WTD-11310; ON: DE94015294; TRN: 94:014676
- Resource Relation:
- Other Information: PBD: May 1994
- Country of Publication:
- United States
- Language:
- English
Similar Records
Tank Waste Retrieval Lessons Learned at the Hanford Site
Project W-320 Tank 106-C waste retrieval study analysis session report
Related Subjects
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
HANFORD RESERVATION
RADIOACTIVE WASTE FACILITIES
REMEDIAL ACTION
RETRIEVAL SYSTEMS
MAINTENANCE
DESIGN
TANKS
WASTE RETRIEVAL
UNDERGROUND STORAGE
054000
052000
HEALTH AND SAFETY
WASTE MANAGEMENT