Technical progress report for the Magnetohydrodynamics Coal-Fired Flow Facility, October 1, 1993--December 31, 1993
In this quarterly technical progress report, UTSI reports on progress in developing the technology for the steam bottoming portion of the MHD Steam Combined Cycle power plant. The experimental program was effectively terminated and reoriented to preparation of reports on previous tests and maintaining the DOE facility. In this report, the results of tube corrosion studies for the samples removed after 500 hours of western coal testing are summarized. Plans for evaluating the tube samples after termination of the tests at 1,047 hours are discussed. The status of development of models to predict ash deposition on conductive heat transfer tubes and their validation with experimental data is presented. Modeling and experiments to induce agglomeration of particulate are also discussed. Significant accomplishments, findings and conclusions include: In summary, corrosion measurements on typical, commercial stainless steels and on low and intermediate chromium steels after 639 hours of LMF5 exposure in the SHTM test sections revealed corrosion that was generally acceptable in magnitude if corrosion kinetics are parabolic, but, except for the higher chromium alloys 253MA and 310, not if kinetics are linear. The production of bilayer scales, and the large amount of scale separation and fragmentation make long term parabolic kinetics unlikely, and result in a high likelihood for breakaway corrosion.
- Research Organization:
- Tennessee Univ., Tullahoma, TN (United States). Space Inst.
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC02-79ET10815
- OSTI ID:
- 10164196
- Report Number(s):
- DOE/ET/10815-225; UTSI-94-02; ON: DE94015047; TRN: 94:007311
- Resource Relation:
- Other Information: PBD: Jun 1994
- Country of Publication:
- United States
- Language:
- English
Similar Records
The Magnetohydrodynamics Coal-Fired Flow Facility
Superheater/intermediate temperature airheater tube corrosion tests in the MHD Coal Fired Flow Facility (Eastern Coal Phase)
Related Subjects
30 DIRECT ENERGY CONVERSION
01 COAL, LIGNITE, AND PEAT
COAL-FIRED MHD GENERATORS
HEAT EXCHANGERS
TUBES
CORROSION
PROGRESS REPORT
BOTTOMING CYCLES
COMBINED-CYCLE POWER PLANTS
200102
300102
300103
014000
POWER CYCLES
PERFORMANCE AND TESTING
MATERIALS, COMPONENTS, AND AUXILIARIES
COMBUSTION