Title: Failure of latch mechanism for motion control of safety rods

Technical Report ·
DOI:https://doi.org/10.2172/10164095· OSTI ID:10164095

During safety rod tests in K-reactor prior to startup, one safety rod could not be lifted because the ``button`` broke off and became lodged in the mechanism. Examination of the failed latch assembly along with other assemblies from both K-Area and L-Area revealed several missing buttons as well as severely deformed ``jaw hanger extensions.`` We participated in the investigation of the damage by request of the Reactor Restart Section. Based on our study of the latch mechanism, the modifications to the ``safety rod extension,`` and the operating history of the machine, this memorandum describes the causes of the observed damage with experimental evidence and calculations to support the findings. 3 refs.