Effect of deposits on corrosion of materials exposed in the Coal-Fired Flow Facility
Conference
·
OSTI ID:10162005
Candidate heat exchanger materials tested in the Low Mass Flow train at the Coal-Fired Flow Facility (CFFF) at Tullahoma, TN. were analyzed to evaluate their corrosion performance. Tube specimens obtained at each foot of the 14-ft-long Unbend tubes were analyzed for corrosion-scale morphologies, scale thicknesses, and internal penetration depths. Results developed on 1500- and 2000- h exposed specimens were correlated with exposure temperature. In addition, deposit materials collected at several locations in the CFFF were analyzed in detail to characterize the chemical and physical properties of the deposits and their influence on corrosion performance of tube materials.
- Research Organization:
- Argonne National Lab., IL (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 10162005
- Report Number(s):
- ANL/ET/CP-78613; CONF-930626-2; ON: DE93015135
- Resource Relation:
- Conference: 31. symposium on engineering aspects of magnetohydrodynamics,Whitefish, MT (United States),29 Jun - 1 Jul 1993; Other Information: PBD: May 1993
- Country of Publication:
- United States
- Language:
- English
Similar Records
Effect of deposits on corrosion of materials exposed in the Coal-Fired Flow Facility
Characterization of deposits and effect of deposits on corrosion of materials for MHD balance-of-plant applications
Results of 500-hour superheater/intermediate temperature airheater tube corrosion tests in the MHD coal fired flow facility
Conference
·
Sat May 01 00:00:00 EDT 1993
·
OSTI ID:10162005
Characterization of deposits and effect of deposits on corrosion of materials for MHD balance-of-plant applications
Technical Report
·
Wed Dec 01 00:00:00 EST 1993
·
OSTI ID:10162005
Results of 500-hour superheater/intermediate temperature airheater tube corrosion tests in the MHD coal fired flow facility
Technical Report
·
Wed May 01 00:00:00 EDT 1991
·
OSTI ID:10162005
Related Subjects
30 DIRECT ENERGY CONVERSION
20 FOSSIL-FUELED POWER PLANTS
36 MATERIALS SCIENCE
IRON BASE ALLOYS
CORROSION
CHROMIUM-NICKEL STEELS
DEPOSITS
CHEMICAL ANALYSIS
POTASSIUM SULFATES
CORROSIVE EFFECTS
MHD GENERATOR CFFF
HEAT EXCHANGERS
SUPERHEATERS
POTASSIUM HYDROXIDES
CHROMATES
MICROSTRUCTURE
300103
200101
200102
360105
MATERIALS, COMPONENTS, AND AUXILIARIES
COOLING AND HEAT TRANSFER EQUIPMENT AND SYSTEMS
POWER CYCLES
CORROSION AND EROSION
20 FOSSIL-FUELED POWER PLANTS
36 MATERIALS SCIENCE
IRON BASE ALLOYS
CORROSION
CHROMIUM-NICKEL STEELS
DEPOSITS
CHEMICAL ANALYSIS
POTASSIUM SULFATES
CORROSIVE EFFECTS
MHD GENERATOR CFFF
HEAT EXCHANGERS
SUPERHEATERS
POTASSIUM HYDROXIDES
CHROMATES
MICROSTRUCTURE
300103
200101
200102
360105
MATERIALS, COMPONENTS, AND AUXILIARIES
COOLING AND HEAT TRANSFER EQUIPMENT AND SYSTEMS
POWER CYCLES
CORROSION AND EROSION