Title: Analysis/control of in-bed tube erosion phenomena in the Fluidized Bed Combustion (FBC) System. Technical progress report No. 5

Technical Report ·
DOI:https://doi.org/10.2172/10161074· OSTI ID:10161074

This technical report summarizes the research work performed and progress achieved during the period of October 1, 1993 to December 31, 1993. Measurement of particle-tube collision frequency was conducted by an electrostatic impact probe in the bench-scale FBC model. Two series of tests were conducted, in one test the probe traversed vertically along the bed axis. The other test conducted that the probe traversed from the center position to the quarter point of bed diagonal and the wall region. The specific weight loss at different tube circumferential was examined to understand the effect of superficial fluidizing velocity. The bottom section of the test tube was found to be more serious erosion than that of the top section. In order to study the effect of tube orientations on in-bed tube erosion, the sample tubes along with four different angles were used. The sample tubes were also placed horizontally and vertically at the center, and vertically near the wall to quantify the effect of the tube location.

Research Organization:
Morgan State Univ., Baltimore, MD (United States). School of Engineering
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
FG22-92MT92021
OSTI ID:
10161074
Report Number(s):
DOE/MT/92021-5; ON: DE94013951; TRN: 94:006552
Resource Relation:
Other Information: PBD: Jan 1994
Country of Publication:
United States
Language:
English