Benchmarking FLOWTRAN, Version 16.2, with an Onset of Significant Voiding (OSV) criterion against measured Onset of Flow Instability (OFI) data from the 1988--89 Columbia University downflow tests has shown that FLOWTRAN with OSV is a conservative OFI predictor. Calculated limiting flow rates based on the Savannah River Site (SRS) OSV criterion were always higher than the measured flow rates at OFI. This work supplements recent FLOWTRAN benchmarking against 1963 downflow tests at Columbia University and 1988 downflow tests at the Heat Transfer Laboratory. These studies provide confidence that using FLOWTRAN with an OSV based criterion for SRS reactor limits analyses will generate operating limits that are conservative with respect to OFI, the criterion selected to prevent fuel damage.