skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Assessment of ISLOCA risk-methodology and application to a combustion engineering plant

Technical Report ·
DOI:https://doi.org/10.2172/10145659· OSTI ID:10145659
; ;  [1]
  1. EG and G Idaho, Inc., Idaho Falls, ID (United States)

Inter-system loss-of-coolant accidents (ISLOCAs) have been identified as important contributors to offsite risk for some nuclear power plants. A methodology has been developed for identifying and evaluating plant-specific hardware designs, human factors issues, and accident consequence factors relevant to the estimation of ISOLOCA core damage frequency and risk. This report presents a detailed of description of the application of this analysis methodology to a Combustion Engineering plant.

Research Organization:
Nuclear Regulatory Commission, Washington, DC (United States). Div. of Safety Issue Resolution; EG and G Idaho, Inc., Idaho Falls, ID (United States)
Sponsoring Organization:
Nuclear Regulatory Commission, Washington, DC (United States)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
10145659
Report Number(s):
NUREG/CR-5745; EGG-2650; ON: TI92013735
Resource Relation:
Other Information: PBD: Apr 1992
Country of Publication:
United States
Language:
English