Beam test of the SDC barrel EM calorimeter test module
Abstract
The SDC barrel electromagnetic calorimeter test module was exposed to beams of high energy pions and electrons in the MP9 test beam at Fermilab in the fall of 1991. Data were collected on resolution, light yield, signal timing and hermiticity. These data demonstrated that the design met the specifications for the barrel electromagnetic calorimeter of the Solenoidal Detector collaboration (SDC).
- Authors:
-
- and others
- Publication Date:
- Research Org.:
- Argonne National Lab. (ANL), Argonne, IL (United States)
- Sponsoring Org.:
- USDOE, Washington, DC (United States)
- OSTI Identifier:
- 10145211
- Report Number(s):
- ANL-HEP-TR-94-16
ON: DE94010461; TRN: 94:008616
- DOE Contract Number:
- W-31109-ENG-38
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: PBD: [1994]
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 43 PARTICLE ACCELERATORS; SHOWER COUNTERS; PERFORMANCE TESTING; ENERGY RESOLUTION; PION BEAMS; ELECTRON BEAMS; 440104; 430303; HIGH ENERGY PHYSICS INSTRUMENTATION; EXPERIMENTAL FACILITIES AND EQUIPMENT
Citation Formats
Balka, L, Guarino, V, and Hill, N. Beam test of the SDC barrel EM calorimeter test module. United States: N. p., 1994.
Web. doi:10.2172/10145211.
Balka, L, Guarino, V, & Hill, N. Beam test of the SDC barrel EM calorimeter test module. United States. https://doi.org/10.2172/10145211
Balka, L, Guarino, V, and Hill, N. 1994.
"Beam test of the SDC barrel EM calorimeter test module". United States. https://doi.org/10.2172/10145211. https://www.osti.gov/servlets/purl/10145211.
@article{osti_10145211,
title = {Beam test of the SDC barrel EM calorimeter test module},
author = {Balka, L and Guarino, V and Hill, N},
abstractNote = {The SDC barrel electromagnetic calorimeter test module was exposed to beams of high energy pions and electrons in the MP9 test beam at Fermilab in the fall of 1991. Data were collected on resolution, light yield, signal timing and hermiticity. These data demonstrated that the design met the specifications for the barrel electromagnetic calorimeter of the Solenoidal Detector collaboration (SDC).},
doi = {10.2172/10145211},
url = {https://www.osti.gov/biblio/10145211},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sun May 01 00:00:00 EDT 1994},
month = {Sun May 01 00:00:00 EDT 1994}
}
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.