skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Beam test of the SDC barrel EM calorimeter test module

Abstract

The SDC barrel electromagnetic calorimeter test module was exposed to beams of high energy pions and electrons in the MP9 test beam at Fermilab in the fall of 1991. Data were collected on resolution, light yield, signal timing and hermiticity. These data demonstrated that the design met the specifications for the barrel electromagnetic calorimeter of the Solenoidal Detector collaboration (SDC).

Authors:
; ;  [1]
  1. and others
Publication Date:
Research Org.:
Argonne National Lab. (ANL), Argonne, IL (United States)
Sponsoring Org.:
USDOE, Washington, DC (United States)
OSTI Identifier:
10145211
Report Number(s):
ANL-HEP-TR-94-16
ON: DE94010461; TRN: 94:008616
DOE Contract Number:  
W-31109-ENG-38
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: [1994]
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 43 PARTICLE ACCELERATORS; SHOWER COUNTERS; PERFORMANCE TESTING; ENERGY RESOLUTION; PION BEAMS; ELECTRON BEAMS; 440104; 430303; HIGH ENERGY PHYSICS INSTRUMENTATION; EXPERIMENTAL FACILITIES AND EQUIPMENT

Citation Formats

Balka, L, Guarino, V, and Hill, N. Beam test of the SDC barrel EM calorimeter test module. United States: N. p., 1994. Web. doi:10.2172/10145211.
Balka, L, Guarino, V, & Hill, N. Beam test of the SDC barrel EM calorimeter test module. United States. https://doi.org/10.2172/10145211
Balka, L, Guarino, V, and Hill, N. 1994. "Beam test of the SDC barrel EM calorimeter test module". United States. https://doi.org/10.2172/10145211. https://www.osti.gov/servlets/purl/10145211.
@article{osti_10145211,
title = {Beam test of the SDC barrel EM calorimeter test module},
author = {Balka, L and Guarino, V and Hill, N},
abstractNote = {The SDC barrel electromagnetic calorimeter test module was exposed to beams of high energy pions and electrons in the MP9 test beam at Fermilab in the fall of 1991. Data were collected on resolution, light yield, signal timing and hermiticity. These data demonstrated that the design met the specifications for the barrel electromagnetic calorimeter of the Solenoidal Detector collaboration (SDC).},
doi = {10.2172/10145211},
url = {https://www.osti.gov/biblio/10145211}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Sun May 01 00:00:00 EDT 1994},
month = {Sun May 01 00:00:00 EDT 1994}
}