Title: Errors of DWPF frit analysis: Final report. Revision 1

Technical Report ·
DOI:https://doi.org/10.2172/10138758· OSTI ID:10138758

Glass frit will be a major raw material for the operation of the Defense Waste Processing Facility. The frit will be controlled by certificate of conformance and a confirmatory analysis from a commercial analytical laboratory. The following effort provides additional quantitative information on the variability of frit chemical analyses at two commercial laboratories. Identical samples of IDMS Frit 202 were chemically analyzed at two commercial laboratories and at three different times over a period of four months. The SRL-ADS analyses, after correction with the reference standard and normalization, provided confirmatory information, but did not detect the low silica level in one of the frit samples. A methodology utilizing elliptical limits for confirming the certificate of conformance or confirmatory analysis was introduced and recommended for use when the analysis values are close but not within the specification limits. It was also suggested that the lithia specification limits might be reduced as long as CELS is used to confirm the analysis.