A measurement of the e/π ratio difference between short (250 ns) and long (2.2 μs) integration times with the D0 uranium-liquid argon central calorimeter
- Michigan State Univ., East Lansing, MI (United States)
The difference of the ratios of the high energy electron and pion responses(e/π) in the DO Uranium-liquid Argon central calorimeter is measured using the DO calorimeter trigger readout (short integration time: 250 ns) and precision readout (long integration time: 2.2 μs). This measurement found a 5% difference in the e/π ratio between short and long integration times, with estimated uncertainty of 2.3%.
- Research Organization:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC02-76CH03000
- OSTI ID:
- 10135821
- Report Number(s):
- DOE/CH/03000-T26; ON: DE94008852; TRN: 94:008480
- Resource Relation:
- Other Information: TH: Thesis (Ph.D.); PBD: 1992
- Country of Publication:
- United States
- Language:
- English