skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Measurement of two-component flow using ultrasonic flowmeters

Conference ·
OSTI ID:10131579
;  [1];  [2];  [3]
  1. Westinghouse Savannah River Co., Aiken, SC (United States)
  2. EG and G Idaho, Inc., Idaho Falls, ID (United States)
  3. Wyle Labs., Norco, CA (United States)

Calibration of transit-time and Doppler ultrasonic flowmeters under two-component flow conditions has been conducted on 400 mm (16-in.) pipe. Testing covered total flows of 0.19 to 1.89 m{sup 3}/s (3000 to 30,000 gpm) and void fractions up to 40%. Both flowmeter types of accurately measured total volumetric flow over a portion of their ranges. Pipe average void fraction, based on a three-beam gamma densitometer, was used to determine water component flow under stratified flow conditions, with similar results. 2 refs.

Research Organization:
Westinghouse Savannah River Co., Aiken, SC (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
10131579
Report Number(s):
WSRC-MS-91-261; CONF-911213-23; ON: DE92010099
Resource Relation:
Conference: American Society of Mechanical Engineers (ASME) annual winter meeting,Atlanta, GA (United States),1-6 Dec 1991; Other Information: PBD: [1991]
Country of Publication:
United States
Language:
English