skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: PERFORMANCE OF THE DIAGNOSTICS FOR NSLS-II LINAC COMMISSIONING

Conference ·
OSTI ID:1013093

The National Synchrotron Light Source II (NSLS-II) is a state of the art 3-GeV third generation light source currently under construction at Brookhaven National Laboratory. The NSLS-II injection system consists of a 200 MeV linac, a 3-GeV booster synchrotron and associated transfer lines. The transfer lines not only provide a means to deliver the beam from one machine to another, they also provide a suite of diagnostics and utilities to measure the properties of the beam to be delivered. In this paper we discuss the suite of diagnostics that will be used to commission the NSLS-II linac and measure the beam properties. The linac to booster transfer line can measure the linac emittance with a three screens measurement or a quadrupole scan. Energy and energy spread are measured in a dispersive section. Total charge and charge uniformity are measured with wall current monitors in the linac and transformers in the transfer line. We show that the performance of the diagnostics in the transfer line will be sufficient to ensure the linac meets its specifications and provides a means of trouble shooting and studying the linac in future operation.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States). National Synchrotron Light Source
Sponsoring Organization:
DOE - Office Of Science
DOE Contract Number:
DE-AC02-98CH10886
OSTI ID:
1013093
Report Number(s):
BNL-94867-2011-CP; 39KC02000; TRN: US1102403
Resource Relation:
Conference: 2011 Particle Accelerator Conference; New York, NY; 20110328 through 20110401
Country of Publication:
United States
Language:
English