Evaluation and comparison of SuperLig{reg_sign} 644, resorcinol-formaldehyde and CS-100 ion exchange materials for the removal of cesium from simulated alkaline supernate
- Pacific Northwest Lab., Richland, WA (United States)
- IBC Advanced Technologies, Inc., Provo, UT (United States)
- 3M Co., St. Paul, MN (United States)
PNL evaluated three polymeric materials for Cs removal efficiency from a simulated Hanford Neutralized Current Acid Waste (NCAW) supernatant liquid using 200 mL ion exchange columns. Cs loadings (mmole Cs/g resin) were 0.20, 0.18, and 0.039 for Super Lig 644, R-F, and CS-100 (0.045, 0.070, 0.011 mmole Cs/mL resin). Elution of each resin material with 0.5 M HNO{sub 3} required 3.5, 7.0, and 3.2 cv to reach 0.1 C/C{sub 0} for the respective materials, resulting in volume compressions of 27, 20, and 6.9. Peak Cs concentrations during elution was 185, 38.5, and 27.8 C/C{sub 0}. SuperLig 644 had the highest Cs loading per gram in NCAW and the greatest volume compression on aci elution. Because of high density and poor elution, R-F had the highest Cs loading per unit volume and lower volume compression. CS-100, the baseline material for Cs removal at Hanford, was inferior to both SuperLig 644 and R-F in terms of Cs loading and selectivity over sodium.
- Research Organization:
- Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 10127404
- Report Number(s):
- PNL-10486; ON: DE95008626
- Resource Relation:
- Other Information: PBD: Mar 1995
- Country of Publication:
- United States
- Language:
- English