The operating characteristics, performance and durability of a hot gas cross flow filter system were evaluated at the Texaco 15 tpd, entrained-bed gasifier pilot plant facility that is located at their Montebello Research Facilities (MRL) in California. A candle filter unit was also tested for comparative purposes. A wide range of operating test conditions were experienced. This report summarizes the results of eleven different test runs that occurred from April 1989 through August 1992. Differences between filter operation on the entrained gasifier and prior experience on fluid bed combustion are discussed.