Title: A comparison of NH{sub 3} point monitoring and diode laser based path integrated measurements

Technical Report ·
DOI:https://doi.org/10.2172/10117878· OSTI ID:10117878
; ; ;  [1]; ;  [2]
  1. Spectral Sciences, Inc., Burlington, MA (United States)
  2. Monitor Labs., Inc., Englewood, CO (United States)

Measurements made using two different types of ammonia monitors during a two-month field study in the summer of 1994 are discussed. The first was a diode-laser based open path monitor designed for automated operation in an industrial environment. The second is a monitoring analyzer based on thermal decomposition of ammonia to NO and subsequent analysis by O{sub 3}-NO chemiluminescence. The two monitors provided consistent measurements of ammonia concentration during weeks of continuous unattended operation.

Research Organization:
Spectral Sciences, Inc., Burlington, MA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
FG02-91ER81196
OSTI ID:
10117878
Report Number(s):
CONF-9411144-4; ON: DE95006892; BR: KM0000000; TRN: AHC29508%%140
Resource Relation:
Conference: Optical sensing for environmental and process monitoring,McLean, VA (United States),7-10 Nov 1994; Other Information: PBD: [1994]
Country of Publication:
United States
Language:
English