Results from evaporation tests to support the MWTF heat removal system design
An experimental tests program was conducted to measure the evaporative heat removal from the surface of a tank of simulated waste. The results contained in this report constitute definition design data for the latest heat removal function of the MWTF primary ventilation system.
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-87RL10930
- OSTI ID:
- 10116389
- Report Number(s):
- WHC-SD-W236A-ER-009; ON: DE95005227; BR: 35AF11201/35AF11202
- Resource Relation:
- Other Information: PBD: 22 Dec 1994