Title: Risk-based Inspection Guide for the Susquehanna Station HPCI system

Technical Report ·
DOI:https://doi.org/10.2172/10111451· OSTI ID:10111451
; ; ;  [1]
  1. Brookhaven National Lab., Upton, NY (United States)

The High Pressure Coolant Injection (HPCI) system has been examined from a risk perspective. A system Risk-based Inspection Guide (S-RIG) has been developed as an aid to HPCI system inspections at the Susquehanna Steam Electric Station (SSES) which is operated by Pennsylvania Power & Light (PP&L). Included in this S-RIG is a discussion of the role of HPCI in mitigating accidents and a presentation of PRA-based failure modes which could prevent proper operation of the system. The S-RIG uses industry operating experience, including plant-specific illustrative examples, to augment the basic PRA failure modes. It is designed to be used as a reference for both routine inspections and the evaluation of the significance of component failures.

Research Organization:
Nuclear Regulatory Commission, Washington, DC (United States). Div. of Radiation Protection and Emergency Preparedness; Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
Nuclear Regulatory Commission, Washington, DC (United States)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
10111451
Report Number(s):
NUREG/CR-5932; BNL-NUREG-52342; ON: TI93004306
Resource Relation:
Other Information: PBD: Nov 1992
Country of Publication:
United States
Language:
English