Title: Performance of the DIII-D 110 GHz ECH system during the first year of operations and testing

Abstract

The first of four Varian 500 kW 110 GHz gyrotrons (VGT-8011) to be used in the new 2 MW 110 GHz electron cyclotron heating system being developed for the DIII-D tokamak was put into test at General Atomics within the last year. This gryotron has been used to demonstrate the overall system efficiency and to validate the design of individual transmission line components. The first plasma heating observed with a 110 GHz was consistent with the power expected for the greater than 85% transmission efficiency of HE{sub 1,1} power. A comparison of the General Atomics` TE{sub 15,2} to HE{sub 1,1} mode converter with the Vlasov-type mode convertor designed by the University of Wisconsin showed similar conversion efficient. The overall ECH system performance during the first year of testing will also be discussed.

Authors:
; ; ;
Publication Date:
Research Org.:
General Atomics, San Diego, CA (United States)
Sponsoring Org.:
USDOE, Washington, DC (United States)
OSTI Identifier:
10104826
Report Number(s):
GA-A-21456; CONF-931018-58
ON: DE94002893; BR: 35AT10020/AT0520210; TRN: 94:000176
DOE Contract Number:  
AC03-89ER51114
Resource Type:
Conference
Resource Relation:
Conference: Symposium on fusion engineering,Hyannis, MA (United States),11-15 Oct 1993; Other Information: PBD: Oct 1993
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION TECHNOLOGY; DOUBLET-3 DEVICE; ECR HEATING; MICROWAVE AMPLIFIERS; PERFORMANCE TESTING; 700460; HEATING AND FUELING SYSTEMS; FUELS

Citation Formats

Wright, A L, Allen, J C, Cary, W P, and Harris, T E. Performance of the DIII-D 110 GHz ECH system during the first year of operations and testing. United States: N. p., 1993. Web.
Wright, A L, Allen, J C, Cary, W P, & Harris, T E. Performance of the DIII-D 110 GHz ECH system during the first year of operations and testing. United States.
Wright, A L, Allen, J C, Cary, W P, and Harris, T E. 1993. "Performance of the DIII-D 110 GHz ECH system during the first year of operations and testing". United States. https://www.osti.gov/servlets/purl/10104826.
@article{osti_10104826,
title = {Performance of the DIII-D 110 GHz ECH system during the first year of operations and testing},
author = {Wright, A L and Allen, J C and Cary, W P and Harris, T E},
abstractNote = {The first of four Varian 500 kW 110 GHz gyrotrons (VGT-8011) to be used in the new 2 MW 110 GHz electron cyclotron heating system being developed for the DIII-D tokamak was put into test at General Atomics within the last year. This gryotron has been used to demonstrate the overall system efficiency and to validate the design of individual transmission line components. The first plasma heating observed with a 110 GHz was consistent with the power expected for the greater than 85% transmission efficiency of HE{sub 1,1} power. A comparison of the General Atomics` TE{sub 15,2} to HE{sub 1,1} mode converter with the Vlasov-type mode convertor designed by the University of Wisconsin showed similar conversion efficient. The overall ECH system performance during the first year of testing will also be discussed.},
doi = {},
url = {https://www.osti.gov/biblio/10104826}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Oct 01 00:00:00 EDT 1993},
month = {Fri Oct 01 00:00:00 EDT 1993}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: