Slug bucket lifting yoke analysis
There are baskets of fuel in the storage pools in the Purex facility (202-A). These baskets (called slug buckets) need to be removed from Purex and taken to the K-Basins. The current slug bucket lifting yoke is of sufficient age to be in question structurally. Therefore new yokes need to be fabricated. Prior to fabricating new yokes, the slug bucket lifting yoke DWG needs to be updated for fabrication. However, the design needs to be refined so that the yoke will be easier to fabricate. These calculations are prepared to demonstrate the adequacy of the new design. The objective of these calculations is to select appropriately sized structural members and weld sizes to serve as components in the slug bucket lifting yoke.
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-87RL10930
- OSTI ID:
- 10104156
- Report Number(s):
- WHC-SD-CP-DA-093; ON: DE95003765; BR: 35AF11201/35AF11202; TRN: AHC29502%%21
- Resource Relation:
- Other Information: PBD: 14 Nov 1994
- Country of Publication:
- United States
- Language:
- English
Similar Records
Analysis of the flexible receiver lifting yoke and blast shield assembly. Tank 241SY101
Multi Canister Overpack (MCO) Design Report [SEC 1 Thru 3]