Title: Ozone Reductions Using Residential Building Envelopes

Abstract

Ozone is an air pollutant with that can have significant health effects and a significant source of ozone in some regions of California is outdoor air. Because people spend the vast majority of their time indoors, reduction in indoor levels of ozone could lead to improved health for many California residents. Ozone is removed from indoor air by surface reactions and can also be filtered by building envelopes. The magnitude of the envelope impact depends on the specific building materials that the air flows over and the geometry of the air flow paths through the envelope that can be changes by mechanical ventilation operation. The 2008 Residential Building Standards in California include minimum requirements for mechanical ventilation by referencing ASHRAE Standard 62.2. This study examines the changes in indoor ozone depending on the mechanical ventilation system selected to meet these requirements. This study used detailed simulations of ventilation in a house to examine the impacts of different ventilation systems on indoor ozone concentrations. The simulation results showed that staying indoors reduces exposure to ozone by 80percent to 90percent, that exhaust ventilation systems lead to lower indoor ozone concentrations, that opening of windows should be avoided at times of high outdoormore » ozone, and that changing the time at which mechanical ventilation occurs has the ability to halve exposure to ozone. Future work should focus on the products of ozone reactions in the building envelope and the fate of these products with respect to indoor exposures.« less

Authors:
; ;
Publication Date:
Research Org.:
Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
Sponsoring Org.:
Environmental Energy Technologies Division
OSTI Identifier:
1008324
Report Number(s):
LBNL-1563E
DOE Contract Number:  
DE-AC02-05CH11231
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; Ozone, Title 24, mechanical ventilation, filtration, ASHRAE Standard 62.2, building envelope, infiltration, simulation

Citation Formats

Walker, Iain S., Sherman, Max, and Nazaroff, William W. Ozone Reductions Using Residential Building Envelopes. United States: N. p., 2009. Web. doi:10.2172/1008324.
Walker, Iain S., Sherman, Max, & Nazaroff, William W. Ozone Reductions Using Residential Building Envelopes. United States. https://doi.org/10.2172/1008324
Walker, Iain S., Sherman, Max, and Nazaroff, William W. 2009. "Ozone Reductions Using Residential Building Envelopes". United States. https://doi.org/10.2172/1008324. https://www.osti.gov/servlets/purl/1008324.
@article{osti_1008324,
title = {Ozone Reductions Using Residential Building Envelopes},
author = {Walker, Iain S. and Sherman, Max and Nazaroff, William W.},
abstractNote = {Ozone is an air pollutant with that can have significant health effects and a significant source of ozone in some regions of California is outdoor air. Because people spend the vast majority of their time indoors, reduction in indoor levels of ozone could lead to improved health for many California residents. Ozone is removed from indoor air by surface reactions and can also be filtered by building envelopes. The magnitude of the envelope impact depends on the specific building materials that the air flows over and the geometry of the air flow paths through the envelope that can be changes by mechanical ventilation operation. The 2008 Residential Building Standards in California include minimum requirements for mechanical ventilation by referencing ASHRAE Standard 62.2. This study examines the changes in indoor ozone depending on the mechanical ventilation system selected to meet these requirements. This study used detailed simulations of ventilation in a house to examine the impacts of different ventilation systems on indoor ozone concentrations. The simulation results showed that staying indoors reduces exposure to ozone by 80percent to 90percent, that exhaust ventilation systems lead to lower indoor ozone concentrations, that opening of windows should be avoided at times of high outdoor ozone, and that changing the time at which mechanical ventilation occurs has the ability to halve exposure to ozone. Future work should focus on the products of ozone reactions in the building envelope and the fate of these products with respect to indoor exposures.},
doi = {10.2172/1008324},
url = {https://www.osti.gov/biblio/1008324}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Sun Feb 01 00:00:00 EST 2009},
month = {Sun Feb 01 00:00:00 EST 2009}
}