Experience report with the Alignment Diagnostic System
Conference
·
OSTI ID:1007543
Since 2009 an Alignment Diagnostic System (ADS) has been operating at the undulator of the new Linac Coherent Light Source at SLAC National Accelerator Laboratory. The undulator spans a distance of 132 meters and is structured into 33 segments. Each segment is equipped with four hydrostatic leveling sensors and four wire position monitors. This report describes the set up and reflects the experience gained with the ADS.
- Research Organization:
- SLAC National Accelerator Lab., Menlo Park, CA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC02-76SF00515
- OSTI ID:
- 1007543
- Report Number(s):
- SLAC-PUB-14299; TRN: US1101443
- Resource Relation:
- Conference: Presented at9th International Workshop On Accelerator Alignment (IWAA 10), DESY, 9/13/2010-9/17/2010
- Country of Publication:
- United States
- Language:
- English