In a recent paper, a physical/mathematical model was developed for neutron coincidence counting, taking explicit account of neutron absorption and leakage, and using dual probability generating function to derive explicit formulae for the single and multiple count-rates in terms of the physical parameters of the system. The results of this modeling proved very successful in a number of cases in which the system parameters (neutron reaction cross-sections, detection probabilities, etc.) remained the same at the various stages of the process (i.e. from collision to collision). However, there are practical circumstances in which such system parameters change from collision to collision, and it is necessary to accommodate these, too, in a general theory, applicable to such situations. For instance, in the case of the neutron coincidence collar (NCC), the parameters for the initial, spontaneous fission neutrons, are not the same as those for the succeeding induced fission neutrons, and similar situations can be envisaged for certain other experimental configurations. This present document shows how the previous considerations can be elaborated to embrace these more general requirements.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
100440
Report Number(s):
BNL-61908; CONF-951006-16; ON: DE95014074
Resource Relation:
Conference: Winter meeting of the American Nuclear Society (ANS), San Francisco, CA (United States), 29 Oct - 1 Nov 1995; Other Information: PBD: [1995]
Country of Publication:
United States
Language:
English

Similar Records

Neutron coincidence measurements with varying parameters
Journal Article · Sun Dec 31 00:00:00 EST 1995 · Transactions of the American Nuclear Society · OSTI ID:100440

Development and evaluation of a list mode neutron coincidence collar for spatial response measurements of fresh fuel assemblies
Journal Article · Mon Jun 15 00:00:00 EDT 2020 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:100440

Development and evaluation of a list mode neutron coincidence collar for spatial response measurements of fresh fuel assemblies
Journal Article · Thu Oct 01 00:00:00 EDT 2020 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:100440