skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information
  1. Carbon nanotube substrates enhance SARS-CoV-2 spike protein ion yields in matrix-assisted laser desorption–ionization mass spectrometry

    Nanostructured surfaces enhance ion yields in matrix-assisted laser desorption–ionization mass spectrometry (MALDI-MS). The spike protein complex, S1, is one fingerprint signature of Sars-CoV-2 with a mass of 75 kDa. Here, we show that MALDI-MS yields of Sars-CoV-2 spike protein ions in the 100 kDa range are enhanced 50-fold when the matrix–analyte solution is placed on substrates that are coated with a dense forest of multi-walled carbon nanotubes, compared to yields from uncoated substrates. Nanostructured substrates can support the development of mass spectrometry techniques for sensitive pathogen detection and environmental monitoring.
  2. Laser–solid interaction studies enabled by the new capabilities of the iP2 BELLA PW beamline

    The new capabilities of the short focal length, high intensity beamline, named iP2, at the BELLA Center will extend the reach of research in high energy density science, including accessing new regimes of high gradient ion acceleration and their applications. This 1 Hz system will provide an on-target peak intensity beyond 1021 W/cm2 with a temporal contrast ratio of <10−14 that will be enabled by the addition of an on-demand double plasma mirror setup. An overview of the beamline design and the main available diagnostics are presented in this paper as well as a selection of accessible research areas. As a demonstrationmore » of the iP2 beamline's capabilities, we present 3D particle-in-cell simulations of ion acceleration in the magnetic vortex acceleration regime. The simulations were performed with pure hydrogen targets and multi-species targets. Proton beams with energy up to 125 MeV and an approximately 12° full angle emission are observed as preplasma scale length and target tilt are varied. The number of accelerated protons is on the order of 109/MeV/sr for energies above 60 MeV.« less
  3. Online charge measurement for petawatt laser-driven ion acceleration

    Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Preclinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultrahigh instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper, we present the first successfulmore » use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a noninvasive diagnostic to measure the charge of the accelerated ion bunch. It enables online estimates of the applied dose in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source, and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics, such as radiochromic films, a Thomson parabola spectrometer, and a scintillator.« less
  4. A new platform for ultra-high dose rate radiobiological research using the BELLA PW laser proton beamline

    Abstract Radiotherapy is the current standard of care for more than 50% of all cancer patients. Improvements in radiotherapy (RT) technology have increased tumor targeting and normal tissue sparing. Radiations at ultra-high dose rates required for FLASH-RT effects have sparked interest in potentially providing additional differential therapeutic benefits. We present a new experimental platform that is the first one to deliver petawatt laser-driven proton pulses of 2 MeV energy at 0.2 Hz repetition rate by means of a compact, tunable active plasma lens beamline to biological samples. Cell monolayers grown over a 10 mm diameter field were exposed to clinically relevant proton dosesmore » ranging from 7 to 35 Gy at ultra-high instantaneous dose rates of 10 7  Gy/s. Dose-dependent cell survival measurements of human normal and tumor cells exposed to LD protons showed significantly higher cell survival of normal-cells compared to tumor-cells for total doses of 7 Gy and higher, which was not observed to the same extent for X-ray reference irradiations at clinical dose rates. These findings provide preliminary evidence that compact LD proton sources enable a new and promising platform for investigating the physical, chemical and biological mechanisms underlying the FLASH effect.« less
  5. A compact, high resolution energy, and emittance diagnostic for electron beams using active plasma lenses

    High-resolution (sub-%), single-shot energy distribution, and emittance measurements of GeV-class electron beams generated by laser plasma accelerators (LPAs) have been enabled through the use of an active plasma lens combined with relatively short dipole magnets. This setup, with only 60 cm between the LPA source and the final diagnostic screen, was facilitated through the use of a replenishable ∼20–40 nm thick liquid crystal plasma mirror to separate remnant laser radiation from the electron beam without emittance degradation. As LPAs capable of generating GeV-class electron beams at cm-scale distances become increasingly ubiquitous, there is a need to supplement these compact accelerators with equallymore » compact diagnostics.« less
  6. Target normal sheath acceleration with a large laser focal diameter

    In this work, the dependence of the laser-driven ion acceleration from thin titanium foils in the Target Normal Sheath Acceleration (TNSA) regime on target and laser parameters is explored using two dimensional particle-in-cell simulations. The oblique incidence (θL = 45°) and large focal spot size (w0 = 40μm) are chosen to take an advantage of quasi one-dimensional geometry of sheath fields and effective electron heating. This interaction setup also reveals low and achromatic angular divergence of a proton beam. It is shown that the hot electron temperature deviates from the ponderomotive scaling for short laser pulses and small pre-plasmas. Thismore » deviation is mainly due to the laser sweeping, as the short duration laser pulse each moment in time effectively heats only a fraction of a focal spot on the foil. This instantaneous partial heating results in an electron temperature deviation from the ponderomotive scaling and, thus, lower maximum proton energies than it could have been expected from the TNSA theory.« less
  7. Laser-heated capillary discharge plasma waveguides for electron acceleration to 8 GeV

    A plasma channel created by the combination of a capillary discharge and inverse Bremsstrahlung laser heating enabled the generation of electron bunches with energy up to 7.8 GeV in a laser-driven plasma accelerator. The capillary discharge created an initial plasma channel and was used to tune the plasma temperature, which optimized laser heating. Although optimized colder initial plasma temperatures reduced the ionization degree, subsequent ionization from the heater pulse created a fully ionized plasma on-axis. The heater pulse duration was chosen to be longer than the hydrodynamic timescale of ≈ 1 ns, such that later temporal slices were more efficientlymore » guided by the channel created by the front of the pulse. Here, simulations are presented which show that this thermal self-guiding of the heater pulse enabled channel formation over 20 cm. The post-heated channel had lower on-axis density and increased focusing strength compared to relying on the discharge alone, which allowed for guiding of relativistically intense laser pulses with a peak power of 0.85 PW and wakefield acceleration over 15 diffraction lengths. Electrons were injected into the wake in multiple buckets and times, leading to several electron bunches with different peak energies. To create single electron bunches with low energy spread, experiments using localized ionization injection inside a capillary discharge waveguide were performed. A single injected bunch with energy 1.6 GeV, charge 38 pC, divergence 1 mrad, and relative energy spread below 2% full-width half-maximum was produced in a 3.3 cm-long capillary discharge waveguide. This development shows promise for mitigation of energy spread and future high efficiency staged acceleration experiments.« less
  8. Ion acceleration in laser generated megatesla magnetic vortex

    © 2019 U.S. Government. Magnetic Vortex Acceleration (MVA) from near critical density targets is one of the promising schemes of laser-driven ion acceleration. 3D particle-in-cell simulations are used to explore a more extensive laser-target parameter space than previously reported in the literature as well as to study the laser pulse coupling to the target, the structure of the fields, and the properties of the accelerated ion beam in the MVA scheme. The efficiency of acceleration depends on the coupling of the laser energy to the self-generated channel in the target. The accelerated proton beams demonstrate a high level of collimationmore » with achromatic angular divergence, and carry a significant amount of charge. For petawatt-class lasers, this acceleration regime provides a favorable scaling of the maximum ion energy with the laser power for the optimized interaction parameters. The megatesla-level magnetic fields generated by the laser-driven coaxial plasma structure in the target are a prerequisite for accelerating protons to the energy of several hundred mega-electron-volts.« less
  9. Absolute calibration of GafChromic film for very high flux laser driven ion beams

    We report on the calibration of GafChromic HD-v2 radiochromic film in the extremely high dose regime up to 100 kGy together with very high dose rates up to 7 × 1011 Gy/s. The absolute calibration was done with nanosecond ion bunches at the Neutralized Drift Compression Experiment II particle accelerator at Lawrence Berkeley National Laboratory (LBNL) and covers a broad dose dynamic range over three orders of magnitude. We then applied the resulting calibration curve to calibrate a laser driven ion experiment performed on the BELLA petawatt laser facility at LBNL. Here, we reconstructed the spatial and energy resolved distributionsmore » of the laser-accelerated proton beams. The resulting proton distribution is in fair agreement with the spectrum that was measured with a Thomson spectrometer in combination with a microchannel plate detector.« less
  10. Control of quasi-monoenergetic electron beams from laser-plasma accelerators with adjustable shock density profile

    The injection physics in a shock-induced density down-ramp injector was characterized, demonstrating precise control of a laser-plasma accelerator (LPA). Using a jet-blade assembly, experiments systematically v aried the shock injector profile, including shock angle, shock position, up-ramp width, and acceleration length. Our work demonstrates that beam energy, energy spread, and pointing can be controlled by adjusting these parameters. As a result, an electron beam that was highly tunable from 25 to 300 MeV with 8% energy spread (ΔEFWHM/E), 1.5 mrad divergence, and 0.35 mrad pointing fluctuation was produced. Particle-in-cell simulation characterized how variation in the shock angle and up-ramp widthmore » impacted the injection process. This highly controllable LPA represents a suitable, compact electron beam source for LPA applications such as Thomson sources and free-electron lasers.« less
...

Search for: