Determination of the Electron Escape Depth for NEXAFS Spectropy
A novel method was developed to determine carbon atom density as a function of depth by analyzing the postedge signal in near-edge X-ray absorption fine structure (NEXAFS) spectra. We show that the common assumption in the analysis of NEXAFS data from polymer films, namely, that the carbon atom density is constant as a function of depth, is not valid. This analysis method is then used to calculate the electron escape depth (EED) for NEXAFS in a model bilayer system that contains a perfluorinated polyether (PFPE) on top of a highly oriented pyrolitic graphite (HOPG) sample. Because the carbon atom densitites of both layers are known, in addition to the PFPE surface layer thickness, the EED is determined to be 1.95 nm. This EED is then used to measure the thickness of the perfluorinated surface layer of poly(4-(1H,1H,2H,2H-perfluorodecyl)oxymethylstyrene) (PFPS).
- Research Organization:
- Brookhaven National Lab. (BNL), Upton, NY (United States). National Synchrotron Light Source
- Sponsoring Organization:
- Doe - Office Of Science
- DOE Contract Number:
- DE-AC02-98CH10886
- OSTI ID:
- 980141
- Report Number(s):
- BNL-93059-2010-JA; LANGD5; TRN: US201015%%1526
- Journal Information:
- Langmuir, Vol. 25, Issue 11; ISSN 0743-7463
- Country of Publication:
- United States
- Language:
- English