Selective Near-UV Ablation of Subgingival Dental Calculus: Measurement of Removal Rates
A noncontact profilometer (laser triangulation) was used to measure the removal rates of subgingival dental calculus irradiated with a frequency-doubled Ti:sapphire laser (60-ns pulse duration, 400-nm wavelength, 10-Hz repetition rate, 7-mJ pulse energy). Profilometer traces before and after irradiation were used to create a removal map with 4-μm axial and 15-μm transverse resolution. Twenty-three teeth (15 with calculus and 8 pristine) were irradiated at 90° and 45° under a cooling water spray with a super-Gaussian beam (~300-μm diameter). Subgingival calculus was selectively removed at 5.6 and 4.0 J/cm2 for 90° and 45°, respecetively, within a range of rates, between 2 to 9 μm/pulse. These ablation rates were constant during these exposures. For comparison, pristine cementum irradiated for 10 min at the same peak fluence and pulse repetition rate showed only craters, 15 to 50 μm deep, corresponding to an equivalent removal rate three orders of magnitude smaller than that obtained for calculus. Pristine enamel was not removed under the same irradiation conditions.
- Research Organization:
- Univ. of Rochester, NY (United States). Lab. for Laser Energetics
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- FC52-08NA28302
- OSTI ID:
- 976959
- Report Number(s):
- DOE/NA/28302-944; 2009-130; 1925
- Journal Information:
- in Lasers in Dentistry XVI, edited by P. Rechmann and D. Fried (SPIE, Bellingham, WA, 2010), Vol. 7549; Conference: BiOS 2010, San Francisco, CA, 23-28 January 2010
- Country of Publication:
- United States
- Language:
- English
Similar Records
Pulsed laser ablation of dental calculus in the near ultraviolet
Laser Ablation of Dental Calculus Around 400 nm Using a Ti:Sapphire Laser