Analysis of Various Pumping Methods With Respect to the Lowest Achievable Ultimate Pressure
Jefferson Labzs CEBAF Accelerator Facility uses most of the currently available vacuum pumping systems for its successful operations.These vacuum systems include turbo, ion, NEG and cryo pumps.The theoretical lowest pressure obtainable with these pumps is different and also the effective pumping speeds of all these pumps at lowest pressures are likely to vary depending on the prevailing conditions. Consequently, the ultimate pressure of a given vacuum system pumped by each of the above mentioned pumps could be expected to vary under the same operating conditions. In this paper the results of the analysis of above pumps with respect to their lowest achievable ultimate pressures are presented.z This work was supported by U.S. Department of Energy Contract No. DE-AC05-84ER40150
- Research Organization:
- Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-84ER40150
- OSTI ID:
- 955223
- Report Number(s):
- JLAB-ACC-03-68; TRN: US1004638
- Resource Relation:
- Conference: Abstract compiled for VACUUM GAS DYNAMICS
- Country of Publication:
- United States
- Language:
- English