Energy Calibration of Gamma Spectra in Plastic Scintillators using Compton Kinematics
Journal Article
·
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, 594(1):232-243
This paper describes a simple and practicable method for assigning energy values to gamma-ray pulse-height distributions measured with polyvinyl toluene based detectors. It is based upon the characteristic shape of the spectrum in the region of maximum energy deposition resulting from a single Compton scattering. The validity of this method is first demonstrated by applying it to a set of NaI(Tl) spectra, and comparing those results to the standard photo-peak method of calibrating the same spectra. The method is then applied to a set of polyvinyl toluene derived spectra.
- Research Organization:
- Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-76RL01830
- OSTI ID:
- 939591
- Report Number(s):
- PNNL-SA-56684; 400904120; TRN: US0806778
- Journal Information:
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, 594(1):232-243, Vol. 594, Issue 1
- Country of Publication:
- United States
- Language:
- English
Similar Records
Erratum to. Energy calibration of gamma spectra in plastic scintillators using Compton kinematics [Nucl. Instr. and Meth. A 594 (2008) 232–243]
Study of Plastic Scintillator Properties for Radioactive Sources Dosimetry - Paper 108
Calibration and performance of the UCR double Compton gamma ray telescope
Journal Article
·
Sun Nov 01 00:00:00 EDT 2009
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:939591
+3 more
Study of Plastic Scintillator Properties for Radioactive Sources Dosimetry - Paper 108
Conference
·
Mon Sep 15 00:00:00 EDT 2014
·
OSTI ID:939591
+1 more
Calibration and performance of the UCR double Compton gamma ray telescope
Conference
·
Sun Apr 01 00:00:00 EST 1990
· IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA)
·
OSTI ID:939591
+5 more
Related Subjects
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
CALIBRATION
COMPTON EFFECT
GAMMA SPECTRA
PLASTIC SCINTILLATORS
POLYVINYLS
TOLUENE
ENERGY ABSORPTION
gamma-ray detection
portal monitor
radiation detection
homeland security
border security
detection of illicit materials
Monte Carlo modeling
detector calibration
CALIBRATION
COMPTON EFFECT
GAMMA SPECTRA
PLASTIC SCINTILLATORS
POLYVINYLS
TOLUENE
ENERGY ABSORPTION
gamma-ray detection
portal monitor
radiation detection
homeland security
border security
detection of illicit materials
Monte Carlo modeling
detector calibration