skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Determination of Neutron Exposure of AISI 304 Stainless Steel from a BWR Top Guide using Retrospective Dosimetry

Journal Article · · Journal of Nuclear Materials, 361(1):1-9

Retrospective dosimetry was used to determine the accumulated neutron exposure of AISI 304 stainless steel removed from the top guide of a boiling water reactor located at the Oyster Creek nuclear power station. The material was removed from areas adjacent to cracks that were observed after ~20 years of operation. Using the plant operational history and a variety of measurements of various radioisotopes or non-radioactive transmutation products produced by irradiation, it was possible to determine the integrated flux spectra experienced by the cracked region and to specify the accumulated displacement dose. Dose estimates on two separate specimens adjacent to the cracks were found to average 1.5 ± 0.2 dpa, possibly reflecting some uncertainty in measurement but more likely suggesting a small gradient in neutron flux-spectra within the section from which the various analysis specimens were cut. This report demonstrates that it is possible to examine defective components lying outside of the core region and where neutron flux-spectra are not well known, and to use the induced transmutation products to determine the neutron exposure with some confidence by using the examined specimen as its own dosimeter.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
902036
Report Number(s):
PNWD-SA-7499; JNUMAM; TRN: US0702753
Journal Information:
Journal of Nuclear Materials, 361(1):1-9, Vol. 361, Issue 1; ISSN 0022-3115
Country of Publication:
United States
Language:
English