Cold Vacuum Drying facility personnel monitoring system design description (SYS 12)
Abstract
This document describes the Cold Vacuum Drying Facility (CVDF) instrument air (IA) system that provides instrument quality air to the CVDF. The IA system provides the instrument quality air used in the process, HVAC, and HVAC instruments. The IA system provides the process skids with air to aid in the purging of the annulus of the transport cask. The IA system provides air for the solenoid-operated valves and damper position controls for isolation, volume, and backdraft in the HVAC system. The IA system provides air for monitoring and control of the HVAC system, process instruments, gas-operated valves, and solenoid-operated instruments. The IA system also delivers air for operating hand tools in each of the process bays.
- Authors:
- Publication Date:
- Research Org.:
- FDH (US)
- Sponsoring Org.:
- ENVIRONMENTAL MANAGEMENT (US)
- OSTI Identifier:
- 797507
- Report Number(s):
- SNF-3066, Rev.0
TRN: US0201661
- DOE Contract Number:
- AC06-96RL13200
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: PBD: 6 Jul 1999
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; RADIOACTIVE WASTE FACILITIES; DESIGN; DRYING; VACUUM SYSTEMS; SPENT FUEL CASKS; PERSONNEL MONITORING
Citation Formats
PITKOFF, C C. Cold Vacuum Drying facility personnel monitoring system design description (SYS 12). United States: N. p., 1999.
Web. doi:10.2172/797507.
PITKOFF, C C. Cold Vacuum Drying facility personnel monitoring system design description (SYS 12). United States. https://doi.org/10.2172/797507
PITKOFF, C C. 1999.
"Cold Vacuum Drying facility personnel monitoring system design description (SYS 12)". United States. https://doi.org/10.2172/797507. https://www.osti.gov/servlets/purl/797507.
@article{osti_797507,
title = {Cold Vacuum Drying facility personnel monitoring system design description (SYS 12)},
author = {PITKOFF, C C},
abstractNote = {This document describes the Cold Vacuum Drying Facility (CVDF) instrument air (IA) system that provides instrument quality air to the CVDF. The IA system provides the instrument quality air used in the process, HVAC, and HVAC instruments. The IA system provides the process skids with air to aid in the purging of the annulus of the transport cask. The IA system provides air for the solenoid-operated valves and damper position controls for isolation, volume, and backdraft in the HVAC system. The IA system provides air for monitoring and control of the HVAC system, process instruments, gas-operated valves, and solenoid-operated instruments. The IA system also delivers air for operating hand tools in each of the process bays.},