Title: Mechanistic facility safety and source term analysis

Conference ·
OSTI ID:782405

A PC-based computer program was created for facility safety and source term analysis at Hanford The program has been successfully applied to mechanistic prediction of source terms from chemical reactions in underground storage tanks, hydrogen combustion in double contained receiver tanks, and proccss evaluation including the potential for runaway reactions in spent nuclear fuel processing. Model features include user-defined facility room, flow path geometry, and heat conductors, user-defined non-ideal vapor and aerosol species, pressure- and density-driven gas flows, aerosol transport and deposition, and structure to accommodate facility-specific source terms. Example applications are presented here.

Research Organization:
Hanford Site (HNF), Richland, WA (United States)
Sponsoring Organization:
US DOE Office of Environmental Management (US)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
782405
Report Number(s):
HNF-4231-FP; TRN: US0204685
Resource Relation:
Conference: Safety Analysis Working Group of EFCOG, Portland, OR (US), 06/13/1999; Other Information: PBD: 9 Jun 1999