skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Kinetics and quantitation of In-111 labeled platelet deposition on control and heparin-bonded polyurethane angio catheters in a dog model

Journal Article · · ASAIO Transactions (American Society for Artificial Internal Organs); (USA)

The dynamics of platelet deposition on control polyurethane catheters (CPC) and heparin-bonded polyurethane catheters (HBPC) were evaluated with In-111 labeled platelets (In-PLT) using a computerized gamma camera (CGC). Ten nonheparinized dogs (18-25 kg) had both femoral arteries catherized with 10 cm of CPC and HBPC (5 Fr.) 24 hr postinjection of 300-420 microcuries of In-PLT, and imaged for 3 hr with a gamma camera. Regional platelet deposition on three segments of catheters and the puncture site was determined. Catheters were harvested and radioactivity on the catheter segments (proximal: PROX, middle: MID, distal: DIST and puncture site: PS) of both was determined. From the platelet count in blood, and radioactivity in blood and segments of catheters, adjacent artery, and area of artery and catheter, the platelet-density (X10(3) (mean +/- S.D.)) on catheter and artery was calculated and tabulated. Proximal values were cath (CPC), 1289 +/- 1125; artery, 1355 +/- 587; cath (HBPC), 125 +/- 113; artery, 1149 +/- 1620. The middle values were cath (CPC), 1102 +/- 1109; artery, 1512 +/- 625; cath (HBPC), 132 +/- 108; artery, 1011 +/- 942. Distal values were cath (CPC), 780 +/- 584; artery, 132 +/- 108; cath (HBPC), 227 +/- 194; artery, 1457 +/- 1309. The puncture site values were cath (CPC), 106 +/- 382; artery, 1011 +/- 942; cath (HBPC), 164 +/- 135; artery, 1498 +/- 1240. The large standard deviation in retained platelets is due to embolization. The platelet-density and regional counts on catheter segments were lower with HBPC than CPC, as was the rate of platelet-deposition.

OSTI ID:
7105556
Journal Information:
ASAIO Transactions (American Society for Artificial Internal Organs); (USA), Vol. 35:3; ISSN 0889-7190
Country of Publication:
United States
Language:
English

Similar Records

The kinetics and quantitation of platelet deposition on control (CPC) and heparin-bonded polyurethane angio-catheter (HBPC) with indium-111 labeled platelets in a dog model
Journal Article · Mon Jan 01 00:00:00 EST 1990 · Progress in Clinical and Biological Research; (USA) · OSTI ID:7105556

The dynamics of platelet thrombus formation rate, thrombus retention time, and rate of embolization on a control and heparin bonded polyurethane angio-catheter
Journal Article · Sun Jul 01 00:00:00 EDT 1990 · ASAIO Transactions (American Society for Artificial Internal Organs); (USA) · OSTI ID:7105556

Use of the 4F Roesch Inferior Mesenteric Catheter in Embolization Procedures in the Pelvis: A Review of 300 Cases
Journal Article · Sun Apr 15 00:00:00 EDT 2007 · Cardiovascular and Interventional Radiology · OSTI ID:7105556