skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: SECO sub 2 (stored energy in CO sub 2 ); Retrofit CO sub 2 bottoming cycles with off-peak energy storage for existing combustion turbines

Conference · · Proceedings of the American Power Conference; (USA)
OSTI ID:7039502
 [1];  [2];  [3]
  1. CBI Na-Con Inc. Oak Brook, IL (USA)
  2. CBI Research Corp. Plainfield, Il (USA)
  3. Virginia Power Glen Allen, VA (USA)

The SECO{sub 2} Power energy storage system is analyzed as a retrofit bottoming cycle for existing Virginia Power combustion turbines (CT's). The closed-loop SECO{sub 2} power system produces on-peak energy using a CO{sub 2} Rankine cycle which rejects heat to {minus} 70{degrees}F stored CO{sub 2} triple point solid; off-peak energy later regenerates the solid. Inherent advantages of the system are shown to be compact storage, minimal environmental impact, and dry-cooled capability, all of which contribute to flexibility in siting and rapid licensing/construction schedules.

OSTI ID:
7039502
Report Number(s):
CONF-880403-; CODEN: PAPWA
Journal Information:
Proceedings of the American Power Conference; (USA), Vol. 50; Conference: American power conference, Chicago, IL (USA), 18-20 Apr 1988; ISSN 0097-2126
Country of Publication:
United States
Language: