The work described in this paper was performed in preparation for establishing a thermoluminescent dosimetry (TLD) system for workers exposed to spontaneous fission neutrons from mixed plutonium isotopes, {sup 232}Th, and depleted uranium at the US Department of Energy (DOE) Pantex facility. The method proposed uses a neutron-insensitive thermoluminescent dosimeter to measure the gamma dose and apply a neutron dose/gamma dose ratio to calculate the neutron dose equivalent. This approach, while requiring multibadge dosimetry for each individual, provides a more accurate neutron dose calculation than was previously in use and reduces the maximum missed dose and falsely reported dose.