skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Evaluation of air pollution abatement systems for multiple-hearth sewage sludge incinerators

Conference ·
OSTI ID:7002137

Capital and annual costs were calculated for the application of six different air-pollution-control system options to municipal sewage-sludge incinerators that were using multiple-hearth furnaces. The systems involved three principal types of air-pollution equipment - wet scrubbers, fabric filters, and electrostatic precipitators - applied to three different plant sizes (plants incinerating 36, 72, and 300 tons of dry sludge per day in one, two, and eight multiple-hearth furnaces, respectively). The six options were: (1) venturi/tray scrubber with a 40-inch pressure drop, (2) fabric filter system operating at 500 deg and equipped with an upstream temperature control, (3) fabric filter system operating at 500 deg and equipped with a heat exchanger and a scrubber for SO/sub 2/ reduction, (4) electrostatic precipitator (ESP) with upstream limited temperature and humidity control, (5) same as Option 4 but with an additional downstream wet scrubber for SO/sub 2/ reduction, and (6) ESP with upstream temperature control and an SO/sub 2/ scrubber. Technical feasibility studies indicated that all three types of controls could achieve a total particulate removal efficiency of 99 percent. The venturi/tray scrubber option entailed the lowest capital cost, but annual operating costs were highest because of the high pressure drops and increased energy use.

Research Organization:
PEI Associates, Inc., Cincinnati, OH (USA)
OSTI ID:
7002137
Report Number(s):
PB-87-100665/XAB
Resource Relation:
Conference: Presented at the annual Air Pollution Control Association conference, Minneapolis, MN, USA, 22-27 Jun, 1986
Country of Publication:
United States
Language:
English