ORNL system for measurement of telephone-line attenuation
The purpose of modifying the TS-100 Automated Tempest Test System software was to use the equipment for making radio-frequency attenuation measurements between an input port and an output port of a telephone network. One set of tests was performed to simulate the electromagnetic radiation from a secure computer terminal and its coupling to telephone lines within a building. Another set of tests was conducted to determine the procedures for measuring attenuation on telephone lines between buildings that are all within the secure zone. The measurements indicate that attenuation between the terminal and the telephone is a function of many variables; however, attenuation in the cable between the buildings is proportional to the length of the cable between the buildings. 1 ref., 2 figs.