skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Effect of reactor conditions on MSIV-ATWS power level

Conference · · Trans. Am. Nucl. Soc.; (United States)
OSTI ID:6941438

In a boiling water reactor (BWR) when there is closure of the main steam isolation valves (MSIVs), the energy generated in the core will be transferred to the pressure suppression pool (PSP) via steam that flows out of the relief valves. The pool has limited capacity as a heat sink and hence, if there is no reactor trip (an anticipated transient without scram (ATWS) event), there is the possibility that the pool temperature may rise beyond acceptable limits. The present study was undertaken to determine how the initial reactor conditions affect the power level during an MSIV-ATWS event. The time of interest is the 20- to 30-min period when it is assumed that the reactor is in a quasi equilibrium condition with the water level and pressure fixed, natural circulation conditions and no control rod movement or significant boron in the core. The initial conditions of interest are the time of the cycle and the operating state.

Research Organization:
Brookhaven National Lab., Upton, NY (USA)
OSTI ID:
6941438
Report Number(s):
CONF-8711195-; TRN: 88-032083
Journal Information:
Trans. Am. Nucl. Soc.; (United States), Vol. 55; Conference: American Nuclear Society winter meeting, Los Angeles, CA, USA, 15 Nov 1987
Country of Publication:
United States
Language:
English