Title: Survey of radon and radon daughter concentrations in selected Rainier Mesa tunnels

Technical Report ·
OSTI ID:6939919

A survey of radon and radon daughter concentrations (RDCs) in selected tunnels on Rainier Mesa at the Nevada Test Site (NTS) was conducted as a part of the underground testing program at NTS. Measurements were taken in three tunnels, N, T, and G. Results of preliminary measurements indicate that N and T Tunnels have low RDCs, i.e., 0.01 WL (working level) (3% of the EPA standard), with normal ventilation conditions. However, it was demonstrated that RDCs can rise to relatively high levels, i.e., 0.24 WL when ventilation rates are significantly lowered. The radon daughter concentrations measured in G Tunnel were an order of magnitude higher than those in N and T Tunnels. The average RDC in the rock mechanics drift (the ''worst-case'' location in G Tunnel) was 0.13 WL with a range from 0.07 WL to 0.23 WL. Elevated RDCs found in the rock mechanics drift of G Tunnel seemed to be attributable to a lower ventilation rate in conjunction with the more highly fractured nature of the ''welded tuff'' rock formation in which the incline drift was mined. By increasing the ventilation rate, a 60% reduction in RDCs from an average of 0.13 Wl to an average of 0.05 WL was achieved.

Research Organization:
Reynolds Electrical and Engineering Co., Inc., Las Vegas, NV (USA)
DOE Contract Number:
AC08-84NV10327
OSTI ID:
6939919
Report Number(s):
DOE/NV/10327-31; ON: DE87005571
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products. Original copy available until stock is exhausted
Country of Publication:
United States
Language:
English