skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Corrosion of selected metal alloys in Utah geothermal waters

Journal Article · · J. Mater. Energy Syst.; (United States)
DOI:https://doi.org/10.1007/BF02833532· OSTI ID:6918964

A potentiodynamic polarization technique has been applied to characterize the corrosion behavior of AISI 316L stainless steel, an iron-based alloy (9Cr-1Mo), a nickel-based alloy (INCONEL/SUP R/ alloy 625), and mild steel ASTM A-36. Corrosion rate was affected greatly by temperature. The pitting potentials decreased with increasing temperature. The nickel-based alloywas resistant to the geothermal water and did not undergo pitting corrosion. All measurements of corrosion--corrosion rate, pit density, maximum pit depth, charge consumed, and polarization resistance--corroborate the decrease in corrosion rate at tested temperatures.

Research Organization:
Corrosion Research Center Univ. of Minnesota, Minneapolis, MN
OSTI ID:
6918964
Journal Information:
J. Mater. Energy Syst.; (United States), Vol. 5:2
Country of Publication:
United States
Language:
English