Title: An analysis of the differences between monitored indoor temperatures and reported thermostat settings

Technical Report ·
OSTI ID:6912292

We examined differences in reported winter thermostat settings and monitored temperatures, and contrasted those households with little difference, and those with a substantial difference. This analysis was conducted on households participating in Bonneville Power Administration's Residential Standards Demonstration Program (RSDP) in the Pacific Northwest. The reported thermostat settings were obtained from a survey of RSDP participants, and indoor temperatures were read from special recorders inside the house. 9 refs., 5 figs., 4 tabs.