skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A simple data loss model for positron camera systems

Conference · · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States)
OSTI ID:6906858
 [1];  [2];  [3]
  1. Karolinska Hospital and Inst., Stockholm (Sweden). Dept. of Clinical Neurophysiology
  2. Max-Planck-Inst. fuer neurologische Forschung, Koeln (Germany)
  3. Univ. of California, Los Angeles, CA (United States). School of Medicine

A simple model to describe data losses in PET cameras is presented. The model is not intended to be used primarily for dead time corrections in existing scanners, although this is possible. Instead the model is intended to be used for data simulations in order to determine the figures of merit of future camera systems, based on data handling state-of-art solutions. The model assumes the data loss to be factorized into two components, one describing the detector or block-detector performance and the other the remaining data handling such as coincidence determinations, data transfer and data storage. Two modern positron camera systems have been investigated in terms of this model. These are the Siemens-CTI ECAT EXACT and ECAT EXACT HR systems, which both have an axial field-of-view (FOV) of about 15 cm. They both have retractable septa and can acquire data from the whole volume within the FOV and can reconstruct volume image data. An example is given how to use the model for live time calculation in a futuristic large axial FOV cylindrical system.

OSTI ID:
6906858
Report Number(s):
CONF-931051-; CODEN: IETNAE
Journal Information:
IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States), Vol. 41:4PT1; Conference: NSS-MIC '93: nuclear science symposium and medical imaging conference, San Francisco, CA (United States), 30 Oct - 6 Nov 1993; ISSN 0018-9499
Country of Publication:
United States
Language:
English

Similar Records

Improved resolution via 3D iterative reconstruction for PET volume imaging
Journal Article · Sun May 01 00:00:00 EDT 1994 · Journal of Nuclear Medicine · OSTI ID:6906858

The ECAT EXACT HR: Performance of a new high resolution positron scanner
Journal Article · Sat Jan 01 00:00:00 EST 1994 · Journal of Computer Assisted Tomography · OSTI ID:6906858

Effect of lead filters on the performance of a neuro-PET tomograph operated without septa
Journal Article · Sun Aug 01 00:00:00 EDT 1993 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6906858