Design and performance of HEAD PENN-PET scanner
Conference
·
· IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States)
OSTI ID:6906790
- Univ. of Pennsylvania, Philadelphia, PA (United States). Dept. of Radiology
- UGM Medical Systems Inc., Philadelphia, PA (United States)
A new PET scanner for brain imaging (and animals) has been designed with very high sensitivity and spatial resolution. The design is an evolution of the PENN-PET scanner, which uses large position-sensitive NaI(Tl) detectors, with Anger-type positioning logic, and which allows 3-D volume imaging, without septa. The new design is built with a single annular crystal coupled to 180 photomultiplier tubes, and uses local triggering electronics to subdivide the detector into small zones and to determine coincident events within the detector. The axial acceptance angle of [+-] 27 deg, with a field-of-view of 25.6 cm, is larger than any currently operating PET scanner. Performance measurements are presented.
- DOE Contract Number:
- FG02-88ER60642
- OSTI ID:
- 6906790
- Report Number(s):
- CONF-931051-; CODEN: IETNAE
- Journal Information:
- IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States), Vol. 41:4PT1; Conference: NSS-MIC '93: nuclear science symposium and medical imaging conference, San Francisco, CA (United States), 30 Oct - 6 Nov 1993; ISSN 0018-9499
- Country of Publication:
- United States
- Language:
- English
Similar Records
Three-dimensional imaging characteristics of the HEAD PENN-PET scanner
Effect of increased axial field of view of on the performance of a volume PET scanner. [Positron Emission Tomography (PET)]
Effect of increased axial field of view of on the performance of a volume PET scanner
Journal Article
·
Tue Apr 01 00:00:00 EST 1997
· Journal of Nuclear Medicine
·
OSTI ID:6906790
Effect of increased axial field of view of on the performance of a volume PET scanner. [Positron Emission Tomography (PET)]
Conference
·
Tue Jan 01 00:00:00 EST 1991
·
OSTI ID:6906790
+1 more
Effect of increased axial field of view of on the performance of a volume PET scanner
Conference
·
Tue Dec 31 00:00:00 EST 1991
·
OSTI ID:6906790
+1 more
Related Subjects
62 RADIOLOGY AND NUCLEAR MEDICINE
BRAIN
POSITRON COMPUTED TOMOGRAPHY
IMAGE SCANNERS
DESIGN
PERFORMANCE
LABORATORY ANIMALS
SPATIAL RESOLUTION
IMAGE PROCESSING
OPTIMIZATION
ANIMALS
BODY
CENTRAL NERVOUS SYSTEM
COMPUTERIZED TOMOGRAPHY
DIAGNOSTIC TECHNIQUES
EMISSION COMPUTED TOMOGRAPHY
NERVOUS SYSTEM
ORGANS
PROCESSING
RESOLUTION
TOMOGRAPHY
550601* - Medicine- Unsealed Radionuclides in Diagnostics
BRAIN
POSITRON COMPUTED TOMOGRAPHY
IMAGE SCANNERS
DESIGN
PERFORMANCE
LABORATORY ANIMALS
SPATIAL RESOLUTION
IMAGE PROCESSING
OPTIMIZATION
ANIMALS
BODY
CENTRAL NERVOUS SYSTEM
COMPUTERIZED TOMOGRAPHY
DIAGNOSTIC TECHNIQUES
EMISSION COMPUTED TOMOGRAPHY
NERVOUS SYSTEM
ORGANS
PROCESSING
RESOLUTION
TOMOGRAPHY
550601* - Medicine- Unsealed Radionuclides in Diagnostics