Multiloop Integral System Test (MIST): Final report
- Babcock and Wilcox Co., Lynchburg, VA (USA). Nuclear Power Div. Babcock and Wilcox Co., Alliance, OH (USA). Research and Development Div.
The Multiloop Integral System Test (MIST) is part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock Wilcox designed plants. MIST is sponsored by the US Nuclear Regulatory Commission, the Babcock Wilcox Owners Group, the Electric Power Research Institute, and Babcock and Wilcox. The unique features of the Babcock Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral facilities to address the thermal-hydraulic SBLOCA questions. MIST and two other supporting facilities were specifically designed and constructed for this program, and an existing facility--the Once-Through Integral System (OTIS)--was also used. Data from MIST and the other facilities will be used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predication abnormal plant transients. The MIST Program is reported in 11 volumes. The program is summarized in Volume 1; Volumes 2 through 8 describes groups of tests by test type, Volume 9 presents inter-group comparisons, Volume 10 provides comparisons between the calculations of RELAP5/MOD2 and MIST observations, and Volume 11 presents the later Phase 4 tests. This Volume 11 pertains to MIST Phase IV tests performed to investigate risk dominant transients and non-LOCA events. 12 refs., 229 figs., 36 tabs.
- Research Organization:
- Nuclear Regulatory Commission, Washington, DC (USA). Div. of Systems Research; Electric Power Research Inst., Palo Alto, CA (USA); Babcock and Wilcox Owners Group, Lynchburg, VA (USA); Babcock and Wilcox Co., Lynchburg, VA (USA). Nuclear Power Div.; Babcock and Wilcox Co., Alliance, OH (USA). Research and Development Div.
- Sponsoring Organization:
- EPRI; USNRC
- OSTI ID:
- 6892374
- Report Number(s):
- NUREG/CR-5395-Vol.11; EPRI-NP-6480-Vol.11; BAW-2067-Vol.11; ON: TI90017699; TRN: 90-029487
- Country of Publication:
- United States
- Language:
- English
Similar Records
Multiloop Integral System Test (MIST) (Final report: Test group 30, Mapping Tests)
Multiloop integral system test (MIST): Test Group 34, Steam generator tube rupture
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
PWR TYPE REACTORS
LOSS OF COOLANT
REACTOR COOLING SYSTEMS
TEST FACILITIES
EXPERIMENTAL DATA
FLOW RATE
HEAT TRANSFER
HYDRAULICS
LEAKS
PROGRESS REPORT
PUMPS
R CODES
REACTOR COMPONENTS
REACTOR SAFETY
RUPTURES
STEAM GENERATORS
T CODES
TESTING
TRANSIENTS
TWO-PHASE FLOW
ACCIDENTS
BOILERS
COMPUTER CODES
COOLING SYSTEMS
DATA
DOCUMENT TYPES
ENERGY SYSTEMS
ENERGY TRANSFER
FAILURES
FLUID FLOW
FLUID MECHANICS
INFORMATION
MECHANICS
NUMERICAL DATA
REACTOR ACCIDENTS
REACTORS
SAFETY
VAPOR GENERATORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
220900* - Nuclear Reactor Technology- Reactor Safety
210200 - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled