Title: The magnetohydrodynamics Coal-Fired Flow Facility

Technical Report ·
OSTI ID:6864196

In this Quarterly Technical Progress Report, UTSI reports on a continuing proof-of-concept (POC) test program for the steam bottoming plant of an MHD/steam combined cycle power plant. In this report, the first POC test on western, low sulfur coal is reported. Analyses of tube materials from the previously completed 2004 hour POC tests on eastern, high sulfur coal are also included. The first test results with the wet electrostatic precipitator (ESP), which was installed to replace the wet venturi scrubber are reported. Detailed results of testing ceramic tubes and test components under a variety of high temperature conditions, for application to a high temperature air heater are included. Progress in application of advanced diagnostics equipment by both UTSI and Mississippi State University (MSU) is summarized. In addition, the laboratory effort to measure the transmissivity and absorption coefficient of the gas in the temperature range of condensing slag and potassium compounds is described. The current status of the CFFF environmental program is summarized.

Research Organization:
Tennessee Univ., Tullahoma, TN (United States). Space Inst.
Sponsoring Organization:
USDOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-79ET10815
OSTI ID:
6864196
Report Number(s):
DOE/ET/10815-197; UTSI-92-08; ON: DE93008883
Country of Publication:
United States
Language:
English