Title: Survey of life-cycle costs of glass-paper HEPA filters

Abstract

We have conducted a survey of the major users of glass-paper HEPA filters in the DOE complex to ascertain the life cycle costs of these filters. Purchase price of the filters is only a minor portion of the costs; the major expenditures are incurred during the removal and disposal of contaminated filters. Through a combination of personal interviews, site visits and completion of questionnaires, we have determined the costs associated with the use of HEPA filters in the DOE complex. The total approximate, life-cycle cost for a glass-paper HEPA filter is $3,000 for one considered low-level waste (LLW), $11,780 for transuranic (TRU) and $15,000 for high-level waste (HLW). The weighted-average cost for a standard HEPA fitter in the complex is $4,753. Although the cost estimate represents an average for all sizes and types of HEPA filters used in DOE facilities, the majority of the fitters are 2 ft [times] 2 ft [times] l ft filters with wooden frames, deep pleated glass-fiber media, and an adhesive sealant.

Authors:
; ;
Publication Date:
Research Org.:
Lawrence Livermore National Lab., CA (United States)
Sponsoring Org.:
USDOE; USDOE, Washington, DC (United States)
OSTI Identifier:
6853742
Report Number(s):
UCRL-JC-109768-Rev.1; CONF-920823-6-Rev.1
ON: DE93005823
DOE Contract Number:  
W-7405-ENG-48
Resource Type:
Conference
Resource Relation:
Conference: 22. Department of Energy (DOE)/Nuclear Regulatory Commission (NRC) air cleaning and treatment conference, Denver, CO (United States), 24-27 Aug 1992
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING; 11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; 12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; AIR FILTERS; LIFE-CYCLE COST; AIR; AIR CLEANING SYSTEMS; GLASS; HANFORD RESERVATION; LEAK TESTING; MAINTENANCE; MATERIALS; ORNL; RADIOACTIVE WASTE DISPOSAL; ROCKY FLATS PLANT; SAVANNAH RIVER PLANT; SERVICE LIFE; STAINLESS STEELS; SURVEYS; TRANSPORT; ALLOYS; COST; ENGINEERED SAFETY SYSTEMS; EQUIPMENT; FILTERS; FLUIDS; GASES; HIGH ALLOY STEELS; IRON ALLOYS; IRON BASE ALLOYS; LIFETIME; MANAGEMENT; NATIONAL ORGANIZATIONS; POLLUTION CONTROL EQUIPMENT; RADIOACTIVE WASTE MANAGEMENT; STEELS; TESTING; US AEC; US DOE; US ERDA; US ORGANIZATIONS; WASTE DISPOSAL; WASTE MANAGEMENT; 420202* - Engineering- Protective Structures & Equipment; 054000 - Nuclear Fuels- Health & Safety; 052002 - Nuclear Fuels- Waste Disposal & Storage

Citation Formats

Moore, P, Bergman, W, and Gilbert, H. Survey of life-cycle costs of glass-paper HEPA filters. United States: N. p., 1992. Web.
Moore, P, Bergman, W, & Gilbert, H. Survey of life-cycle costs of glass-paper HEPA filters. United States.
Moore, P, Bergman, W, and Gilbert, H. 1992. "Survey of life-cycle costs of glass-paper HEPA filters". United States.
@article{osti_6853742,
title = {Survey of life-cycle costs of glass-paper HEPA filters},
author = {Moore, P and Bergman, W and Gilbert, H},
abstractNote = {We have conducted a survey of the major users of glass-paper HEPA filters in the DOE complex to ascertain the life cycle costs of these filters. Purchase price of the filters is only a minor portion of the costs; the major expenditures are incurred during the removal and disposal of contaminated filters. Through a combination of personal interviews, site visits and completion of questionnaires, we have determined the costs associated with the use of HEPA filters in the DOE complex. The total approximate, life-cycle cost for a glass-paper HEPA filter is $3,000 for one considered low-level waste (LLW), $11,780 for transuranic (TRU) and $15,000 for high-level waste (HLW). The weighted-average cost for a standard HEPA fitter in the complex is $4,753. Although the cost estimate represents an average for all sizes and types of HEPA filters used in DOE facilities, the majority of the fitters are 2 ft [times] 2 ft [times] l ft filters with wooden frames, deep pleated glass-fiber media, and an adhesive sealant.},
doi = {},
url = {https://www.osti.gov/biblio/6853742}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Dec 01 00:00:00 EST 1992},
month = {Tue Dec 01 00:00:00 EST 1992}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: