Title: Temperature distributions in well-insulated and closed/nearly closed-ended vertical pipes

Conference · · Transactions of the American Nuclear Society; (USA)
OSTI ID:6852607

Many different sized auxiliary lines are tied into the primary heat transport system piping of nuclear reactors and other similar types of systems. Often these lines are valve closed so that the contained fluid is either stagnant or flowing at low velocity due to free convection or small amounts of leakage (across valves). The characterization of the axial temperature distributions in these lines is important because of potential structural consequences to the pipe. For example, in addition to being required for determining basic thermal expansion allowances in piping networks, it is needed relative to other considerations such as thermal fatigue, which could occur due to leakage attaining a different temperature than that of the trunk line that it flows into. As would be anticipated, conditions that result in larger fluid temperature differences at a particular network juncture generally result in the more severe structural impact (e.g., thermal stratification/striping assessments become necessary). The purpose of this paper was to characterize some of the major phenomena that needed to be considered relative to predicting the range of temperature variations that can be experienced in the piping. The major emphases of these discussions are on vertical pipe orientation (either up or down).

OSTI ID:
6852607
Report Number(s):
CONF-890604-; CODEN: TANSA; TRN: 90-023195
Journal Information:
Transactions of the American Nuclear Society; (USA), Vol. 59; Conference: Annual meeting of the American Nuclear Society, Atlanta, GA (USA), 4-8 Jun 1989; ISSN 0003-018X
Country of Publication:
United States
Language:
English