Title: New York State Electric and Gas Corporation`s Milliken Station clean coal technology demonstration project and its impacts on the local ambient air quality

Conference ·
OSTI ID:679381
 [1]; ;  [2]
  1. ENSR Corp., Acton, MA (United States)
  2. New York State Electric and Gas Corp., Binghamton, NY (United States)

New York State Electric and Gas Corporation (NYSEG) has recently completed a program which upgraded the boiler combustion system and installed a high-efficiency flue gas desulfurization (FGD) system to demonstrate innovative emissions control technology and comply with the Clean Air Act Amendments of 1990. The demonstration project was conducted at NYSEG`s Milliken Station, in the Town of Lansing, New York. The primary objective of this clean coal technology demonstration (CCTD) project was to demonstrate a retrofit of energy-efficient SO{sub 2} and NO{sub x} control systems with minimal impact on overall plant efficiency. A four-year ambient monitoring program was conducted to evaluate the effects of the FGD system and combustion modifications on the local ambient air quality, the results of which are summarized in this paper. As part of NYSEG`s Milliken Station Clean Coal Technology Demonstration project, a flue gas desulfurization system was added as well as modifications to the combustion system and electrostatic precipitators. The demonstration project added a forced oxidation, formic acid-enhanced wet limestone FGD system, which was expected to reduce SO{sub 2} emissions by at least 90 percent. The project scope also consisted of combustion modifications and selective non-catalytic reduction (SNCR) technology to reduce NOx emissions. The burners were replaced with Low NOx Concentric Firing System Level 3 (LNCFS-3) burners to reduce NOx emissions while maintaining high combustion efficiency and acceptable fly ash loss on ignition (LOI). The electrostatic precipitators (ESP) on the two 160 MWe boilers were also upgraded to accommodate the wet flue gas desulfurization system. Upgrades of the ESP on each unit consisted of replacement of the internals and retirement of part of the original ESP.

OSTI ID:
679381
Report Number(s):
CONF-980632-; TRN: IM9940%%200
Resource Relation:
Conference: 91. annual meeting and exhibition of the Air and Waste Management Association, San Diego, CA (United States), 14-18 Jun 1998; Other Information: PBD: 1998; Related Information: Is Part Of Proceedings of the 91. annual meeting and exhibition. Bridging international boundaries: Clean production for environmental stewardship; PB: [5000] p.
Country of Publication:
United States
Language:
English