skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Evaluation of cobalt sources in Westinghouse-designed three- and four-loop plants. Final report

Technical Report ·
OSTI ID:6736593

Sources of cobalt input in two typical Westinghouse-designed three- and four-loop plants are identified. Quantification of the sources was based on a detailed analysis of the construction materials. The best available information was used to establish the corrosion and wear release rates. This analysis concludes that approximately 70% of the cobalt input arises from corrosion release of Inconel steam generator tubing. Corrosion and wear of high-cobalt alloys account for about 25%. Recommendations are made concerning cobalt reduction options based on a cost-benefit analysis.

Research Organization:
Westinghouse Electric Corp., Pittsburgh, PA (USA). Nuclear Technology Div.
OSTI ID:
6736593
Report Number(s):
EPRI-NP-2681; ON: DE83900563
Resource Relation:
Other Information: Portions of document are illegible
Country of Publication:
United States
Language:
English

Similar Records

Development of LWR Fuels with Enhanced Accident Tolerance ATF Feasibility Analysis Report Deliverable for the Westinghouse Accident Tolerant Fuel Program
Technical Report · Wed Jun 06 00:00:00 EDT 2018 · OSTI ID:6736593

Reducing the cobalt inventory in light water reactors
Journal Article · Tue Jan 01 00:00:00 EST 1985 · Nucl. Technol.; (United States) · OSTI ID:6736593

A parametric study of an anticipated transient without scram in a Westinghouse four-loop plant
Journal Article · Sun Feb 01 00:00:00 EST 1987 · Nucl. Technol.; (United States) · OSTI ID:6736593