skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Hot spot(s) of the lung in technetium-99m albumin colloid liver-spleen scintigraphy: case report

Journal Article · · J. Nucl. Med. Technol.; (United States)
OSTI ID:6618163

The authors replaced /sup 99m/Tc albumin colloid for /sup 99m/Tc sulfur colloid as a radiopharmaceutical for liver-spleen imaging and found two instances of hot spot(s) in the lung. The preparation procedure of albumin colloid is easier and more convenient as compared to that of sulfur colloid. Whereas replacement of /sup 99m/Tc sulfur colloid by /sup 99m/Tc albumin colloid is inevitable, it should be emphasized that one should avoid blood withdrawal in the syringe containing albumin colloid to prevent formation of clot(s) during the venous puncture for /sup 99m/Tc albumin colloid.

Research Organization:
Univ. of Kentucky Medical Center, Lexington (USA)
OSTI ID:
6618163
Journal Information:
J. Nucl. Med. Technol.; (United States), Vol. 16:2
Country of Publication:
United States
Language:
English

Similar Records

Lung uptake on Tc-99m albumin colloid liver spleen scan and on Ga-67 scan in angiotropic lymphoma
Journal Article · Thu Mar 01 00:00:00 EST 1990 · Clinical Nuclear Medicine; (USA) · OSTI ID:6618163

Experience with technetium-99m albumin colloid kit for reticuloendothelial system imaging
Journal Article · Mon Sep 01 00:00:00 EDT 1986 · J. Nucl. Med. Technol.; (United States) · OSTI ID:6618163

Dose to the liver and spleen in pediatric patients undergoing technetium-99m sulfur colloid scans
Journal Article · Thu Nov 01 00:00:00 EST 1979 · Radiology; (United States) · OSTI ID:6618163