MR imaging of middle cerebral artery stenosis and occlusion: Value of MR angiography
- Suita Municipal Hospital, Osaka (Japan)
- Osaka Univ. Medical School (Japan)
To investigate the effectiveness of MR angiography in conjunction with spin-echo imaging for evaluating vascular patency in patients with middle cerebral artery (MCA) stenosis or occlusion. Seven patients with MCA stenosis or occlusion, verified with contrast angiography in five and correlated with transcranial Doppler sonography in two, were examined using two-dimensional and/or three-dimensional time-of-flight MR angiographic techniques as well as conventional spin-echo imaging. Of the seven patients, six demonstrated basal ganglionic and/or cortical infarct in the MCA territory. Except one case with minimal stenosis immediately distal to the MCA origin, all six cases with either severe stenosis or occlusion of the main trunk of the MCA showed the absence of normal flow voids using spin-echo imaging in the sylvian fissure on the affected side. However, it was not possible to discriminate between stenosis and occlusion. Although different mechanisms (i.e., flow-induced spin dephasing for the 2-D technique and progressive spin saturation for the 3-D technique) were predominantly responsible for the loss of signal through the area of stenosis, both the 2-D and 3-D MR angiograms clearly depicted the compromised flow of the MCA: a focal discontinuity with decreased vessel caliber corresponded to stenosis, and nonvisualization of distal MCA branches represented occlusion. Either 2-D or 3-D time-of-flight MR angiography is a useful adjunct to conventional parenchymal spin-echo imaging for evaluating vascular patency in patients with MCA stenosis or occlusion, although it is important to recognize that each technique has a different basis for the loss of signal through the area of stenosis. 13 refs., 4 figs., 1 tab.
- OSTI ID:
- 6552798
- Journal Information:
- AJNR. American Journal of Neuroradiology; (United States), Vol. 15:2; ISSN 0195-6108
- Country of Publication:
- United States
- Language:
- English
Similar Records
Routine Use of Three-Dimensional Contrast-Enhanced Moving-Table MR Angiography in Patients with Peripheral Arterial Occlusive Disease: Comparison with Selective Digital Subtraction Angiography
Peripheral vascular disease: correlation of MR imaging and angiography
Related Subjects
62 RADIOLOGY AND NUCLEAR MEDICINE
BIOMEDICAL RADIOGRAPHY
COMPARATIVE EVALUATIONS
CEREBRAL ARTERIES
VASCULAR DISEASES
DIAGNOSTIC TECHNIQUES
BRAIN
MAGNETIC RESONANCE
SPIN ECHO
TIME-OF-FLIGHT METHOD
ARTERIES
BLOOD VESSELS
BODY
CARDIOVASCULAR SYSTEM
CENTRAL NERVOUS SYSTEM
DISEASES
EVALUATION
MEDICINE
NERVOUS SYSTEM
NUCLEAR MEDICINE
ORGANS
RADIOLOGY
RESONANCE
550900* - Pathology
550602 - Medicine- External Radiation in Diagnostics- (1980-)